The design cooker hoods must be installed at a minimum distance of 550 mm from the electric hobs and 650 mm from the gas hobs.
They are conceived to be connected to a pipe with a diameter of 150 mm, anyway in front of possible special needs we supply them with a reducer that allows also to use connection to pipe with diameter of 120 mm.
As a principle you can consider that the air delivery of the hood decreases with the length of the pipe, or with the number of the curves, or with the reduction of the pipe section.
We strongly advice to keep the length of the pipe as short as possible, to avoid installation with many curves and to use pipes with 150 mm diameter.
This symbol is present in models it is possible to mount the hood at lower distances then the above, as shown in the manual attached to the product.